Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Opt Express ; 24(13): 14260-70, 2016 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-27410582

RESUMO

Development of efficient soft x-ray laser plasma amplifiers adapted to seeded operation, requires a better control over amplifier transverse spatial extent, brilliance control and gain lifetime. Here it is shown that pumping the plasma amplifier with one long and two short pump pulses (1L2S) provides advantages in terms of control for the specified parameters in the case of Ni-like Ag x-ray laser. Also, significant tunability of the gain lifetime in the 1L2S pumping scheme for Ne-like Ti x-ray laser is observed. Direct harmonics seeding and chirped harmonics seeding amplification approaches may benefit from the control of the gain lifetime, in terms of better use of the pump energy and as a way to reduce the amplified spontaneous emission in x-ray lasers.

2.
Opt Lett ; 39(13): 3770-3, 2014 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-24978733

RESUMO

We show that a significant enhancement of the photon flux produced by high harmonic generation can be obtained through guided configuration at high laser intensity largely above the saturation intensity. We identify two regimes. At low pressure, we observe an intense second plateau in the high harmonic spectrum in argon. At relatively high pressure, complex interplay between strongly time-dependent ionization processes and propagation effects leads to important spectral broadening without loss of spectral brightness. We show that the relevant parameter for this physical process is the product of laser peak power by gas pressure. We compare source performances with high harmonic generation using a gas jet in loose focusing geometry and conclude that the source developed is a good candidate for injection devices such as seeded soft x-ray lasers or free electron lasers in the soft x-ray range.

3.
Opt Lett ; 38(20): 4011-4, 2013 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-24321908

RESUMO

The wavefront of an injection-seeded soft x-ray laser beam generated by amplification of high-harmonic pulses in a λ=18.9 nm molybdenum plasma amplifier was measured by a Hartmann wavefront sensor with an accuracy of λ/32 root mean square (rms). A significant improvement in wavefront aberrations of 0.51±0.03λ rms to 0.23±0.01λ rms was observed as a function of plasma column length. The variation of wavefront characteristic as a function time delay between the injection of the seed and peak of soft x-ray amplifier pump was studied. The measurements were used to reconstruct the soft x-ray source and confirm its high peak brightness.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...